Product Description
MR089E Power System Trainer (PSS1): A self-contained unit that simulates all parts of electrical power lab equipment electrical laboratory equipment for universityPower System Trainer (PSS1): A self-contained unit that simulates all parts of electrical power systems and their protection, from generation to utilizationKey Features Simulates generation, transmission, transformation, distribution, utilization and protection in one self-contained unitIncludes prime mover and generator to simulate power generationTwin distribution transformers for parallel transformer and load flow testsIncludes industrial-standard digital protection relays for realistic trainingKey Specifications Prime mover and generator Eleven protection relaysTwin distribution transformersSwitched busbar with six feedersSeven transmission linesTwo distribution loads Two utilization loads
•One dynamic loadDescription The Power System Trainer contains everything needed to teach students how electrical power systems work. It is a self-contained unit (only needs electrical power) with full safety features. It includes all the main parts of an electrical power system, from supply (generation) to demand (utilization). Each part includes dedicated industrial-standard protection relays that do specific jobs, from generator protection to distance protection on transmission lines, and distribution transformer protection.Generator and grid supply The Power system trainer has a motor (prime mover) and generator set to simulate power generation. This set has characteristics similar to industrial turbine and generator sets for realistic experiments. The output of the generator passes through a generator transformer to a 'generator bus'. Protection relays and circuit-breakers monitor and switch the generator field and output. The Power system trainer includes a fully monitored and protected grid supply transformer. This transformer simulates the larger grid transformers used in national grid supply systems. The grid transformer reduces the incoming mains supply to give the correct distribution voltage at the 'grid bus'. It also allows students to correctly synchronize the generator output to the grid supply. For realistic tests, students can use the grid supply or the generator as a power source for their experiments. Transmission lines
A set of reactances simulate transmission lines of different lengths to model the characteristics of overhead or underground power cables. Each line includes test points to monitor the conditions along the lines. The user can simulate faults at different places along the transmission lines and discover the effects. A dedicated distance protection relay protects the lines and can indicate how far along the line the fault has occurred.Transformation, distribution and utilization As well as the grid supply and generator transformers, the Power System Trainer has two identical distribution transformers to simulate the distribution transformers fitted near to factories or houses. These transformers have variable tapping and feed a 'utilization bus'. Dedicated relays protect the transformers and can work in different ways, determined by student experiments. The utilization bus simulates electrical consumers (houses and factories). It includes variable resistive, capacitive and inductive loads, with an induction motor (dynamic) load. A switched busbar section includes a main bus and a standby or 'reserve bus'. These simulate a real bus switching system in a power plant or power distribution station. Protection relays and circuit-breakers monitor and switch the incoming and outgoing feeders of the busbar. One feeder of the busbar has a 'point-on-wave' circuit breaker for studies of switching transients.Detailed Specifications a) Voltages:Distribution: 415 V three-phase line to lineUtilization: 415 V three-phase line to line
Grid transformer: 5 kVA delta to star (Dy11) Primary is matched to the incoming three-phase supply to give the 220 V three-phase line-to-line secondary distribution voltage. Includes earth link for the secondary star point and a selectable tapping earth resistor for restricted earth fault protection tests.Generator and prime mover: 6 kVA maximum (operated at a nominal 2 kVA), four pole salient pole a.c generator Brushless, with automatic and manual excitation.7 kVA maximum induction motor with shaft encoder and electronic four-quadrant a.c vector-drive control, with a four-position drive inertia switchGenerator transformer:1:1 ratio delta-to-star (Dy11) impedance matching with adjustable secondary tappingTransmission lines: Line reactances simulate 'per unit' (pu) values of impedance: Line 1: 0.10 pu Lines 2 and 3: 0.15 pu Lines 4 and 5: 0.25 puLine 6: 5 x 0.1 pu length with four test points and dedicated three-zone distance protectionLine 7: 4 x 0.01 pu (cable) Capacitors are provided adjacent to the lines. Each capacitor has selectable values and may be inserted in circuit to give π or T-line configurations for studies of losses.Distribution transformers: Two identical 2 kVA transformers, 415 V to 220 V Star-to-delta Yd1 Adjustable primary tapping and matched impedances Switched busbar:Six bi-directional feeders, each with circuit-breakers - one circuit breaker is a 'point-on-wave' deviceTwo circuit-breakers to break each half of each busTwelve bus isolators, six on each half of the busTwo circuit-breakers that break the coupling between the main and reserve bus
Protection relays: Grid transformer protection Grid bus protection Generator protectionGenerator bus protection Distance protection 2 x double bus protection 4 x distribution transformer protectionLoads: Two separate 415 V (distribution) loads, each with delta-connected variable resistors and inductors; one load is near to the generator and the other near to the distribution bus. Two sets of 415 V (utilization) loads at the utilization bus; each has delta-connected variable resistors, inductors and capacitor banks.One dynamic load - an induction motor at the utilization busElectrical supply: Three-phase 10 kW, 50 Hz Learning Outcomes Power transmission, distribution and utilizationLoad flow, circuit interruption and differential protectionSymmetrical, unsymmetrical and unbalanced faults and loads Generator synchronization and performance, including stability and voltage regulation and controlUsing protection relays for overcurrent, distance protection, phase and earth faultsUsing protection relays for differential protection, under and overvoltage and frequency protection Transformer tapping and impedances Using relays for protection of a busbar, transformers and generatorsServiceWe supply supply7*24 hours service, customer design service, OEM service, buyer label service. With professional engineers team and sales team, we assure you good product quality.CertificateOur products takes ISO9001 product management system.No. | Feature Name | Details |
1 | Customer design | Yes |
2 | Warranty | 1 year, 2 years, 3 years or 5 years according to client requirements |
3 | Package | Plastic film+ carton+ Fine plywood |
4 | Products standard | International didactic equipment standard |
5 | Application range | Educational equipment for university, college, vocational training centers |
6 | Company philosophy | Supply best quality Chinese products to the worldwide schools. |
7 | Self owned brand | Minrry,MR |
8 | Production time | From 10 days to 60 days according to different items |
We also have below equipment, please click the link to see itelectrical training equipmentmechatronics training equipment
Address:
Building No. 3 Double Innovation and Creation Industry Center, No. 803 Keyuan Road, High Tech Zone, Jinan, Shandong, China
Business Type:
Manufacturer/Factory
Business Range:
Office Supplies
Management System Certification:
ISO 9001
Company Introduction:
Jinan Minrry Technology Equipment Co., Ltd. Established in 2009, is a factory of manufacture educational equipment, vocational training equipment, didactic equipment. Minrry is Shandong Provincial High Tech and Innovation company, with self develop and research engineers team, with self owned 5000 square meters factory.
Past ISO9001, IS14001, OHSAS18001 certificats.
Minrry products exports for more than 100 countries.
Our product ranges are as belows:
Electrical training equipment
Mechatronics training equipment
Fluid lab equipment
Thermal training equipment
Refrigeration training equipment
PCB lab equipment
Our company offers variety of products which can meet your multifarious demands. We adhere to the management principles of "quality first, customer first and credit-based" since the establishment of the company and always do our best to satisfy potential needs of our customers. Our company is sincerely willing to cooperate with enterprises from all over the world in order to realize a win-win situation since the trend of economic globalization has developed with anirresistible force.